Product Catalog

Mini-Split Heat Pump Series

Spartan AC's 36k BTU Minisplit system

The Spartan Mini-Split Series covers a full range of heating & cooling needs.

Residential to commercial. Plug-in to dedicated circuit. 12,000 to 36,000 BTU.

The Spartan Mini-Split Series is a complete air conditioning solution, engineered for straightforward installs and long service life. SEER2 ratings up to 20. Backed by the Spartan warranty and supported by the same parts and service network.

  • The 12K runs on a standard 115V outlet, making it the only unit in the line that installs without a dedicated circuit.
  • The 18K and 24K share a SEER2 19 rating and cover the mid-to-large room range on 220V.
  • The 36K is the high-capacity option for demanding installs where output is the priority.


36,000 BTU/h · 208-230V

36K Max

Cooling 36,000 Btu/h
SEER2 17

23,000 BTU/h · 208-230V

24K Pro

Cooling 5,460–24,225 Btu/h
SEER2 19

18,000 BTU/h · 208-230V

18K Standard

Cooling 4,430–18,700 Btu/h
SEER2 19

12,000 BTU/h · 115V

12K Compact

Cooling 2,728–13,981 Btu/h
SEER2 20

Specifications

Unit Comparison

Mini-Split Heat Pump Series
Specification 36k-220v 24k-220v 18k-220v 12k-115v
Power Supply
Voltage 208-230 V 208-230 V 208-230 V 115 V
Phase 1 1 1 1
Frequency 60 Hz 60 Hz 60 Hz 60 Hz
Efficiency
SEER 17 - - -
HSPF 8 - - -
Rated Capacity
Cooling Btu/h 36,000 5,460–24,225 4,430–18,700 2,728–13,981
Cooling W 1,800–10,000 1,600–7,100 1,300–5,500 800–4,100
Heating Btu/h 36,000 5,460–25,930 4,430–19,100 2,728–15,004
Heating W 1,800–10,000 1,600–7,600 1,300–5,600 800–4,400
Dehumidifying 3.6 kg/h / 7.61 pt/h 2.36 kg/h / 4.98 pt/h 1.6 kg/h / 3.38 pt/h 1 kg/h / 2.1 pt/h
Performance
Cooling Power (W) 300–3,700 350–2,300 290–2,100 230–1,400
Heating Power (W) 300–3,400 350–2,400 250–1,800 250–1,400
Cooling Current (A) 1–16 1.6–10.5 2.2–10 2–12.4
Heating Current (A) 1–16 1.6–11 2–9 2.2–12.4
Max Input Power 3700 W 3400 W 2200 W 1600 W
Max Input Current 17 A 16 A 12 A 14 A
Refrigerant & Pressure
Refrigerant Charge 2000 g / 70.50 oz 1300 g / 45.90 oz 1000 g / 35.30 oz 500 g / 17.60 oz
Max Discharge Pressure 4.3 MPa 4.3 MPa 4.3 MPa 4.3 MPa
Max Suction Pressure 2.5 MPa 2.5 MPa 2.5 MPa 2.5 MPa
Air Flow 1600 m³/h / 942 CFM 1300 m³/h / 765 CFM 850 m³/h / 500 CFM 600 m³/h / 353 CFM
Noise
Indoor Peak - Up to 50 dB(A) Up to 47 dB(A) Up to 42 dB(A)
Outdoor 58 dB(A) 57 dB(A) 54 dB(A) 52 dB(A)
Indoor Cooling by Speed - 50 / 47 / 43 / 39 / 30 dB(A) 47 / 43 / 40 / 37 / 29 dB(A) 42 / 40 / 38 / 35 / 27 dB(A)
Indoor Unit
Indoor Packing Type 6-face - - -
Indoor Net Dimensions 1250 × 360 × 253 mm 1132 × 330 × 232 mm 940 × 316 × 224 mm 792 × 292 × 201 mm
Indoor Liquid Stop Valve DG4 DG4 DG4 DG4
Indoor Gas Stop Valve DG13 DG13 DG10 DG8
Outdoor Unit
Compressor GMCC KTM240D43UKUA2 GMCC KTN150D43UFZC31 GMCC KSN140D53UFZM3 GMCC KSN98D35UER31
Outdoor Net Dimensions 900 × 700 × 350 mm 823 × 655 × 302 mm 785 × 300 × 555 mm 705 × 279 × 530 mm
Weights
Indoor Net Weight 16 kg / 35.3 lbs 14 kg / 30.9 lbs 11.5 kg / 23.0 lbs 8 kg / 17.6 lbs
Outdoor Net Weight 46 kg / 101.4 lbs 32 kg / 70.5 lbs 29.5 kg / 59.0 lbs 23.5 kg / 51.8 lbs
Container Loading
20ft Container 42 units 66 units 87 units 102 units
40ft Container 113 units 138 units 180 units 216 units
40HQ Container 126 units 159 units 208 units 256 units